FRCAC/DC voltage dividerBy connecting the instrument line to the high-voltage measuring terminal, clear readings can be obtained from a distance, making it safe and convenient to use. This series of digital voltage dividers has high input impedance and good linearity. Special shielding technology is used to reduce the impact of high voltage on the indication, achieving high stability and linearity.
The FRC series digital voltage divider is a resistive capacitive equipotential shielding high-voltage measuring device. Mainly used for measuring pulse high voltage, lightning high voltage, and power frequency high voltage. Can replace high-voltage electrostatic voltmeter. It has the characteristics of easy operation, intuitive display, high accuracy, small size, and light weight, and is suitable as an ideal equipment for high-voltage measurement in power plants, substations, high-voltage electrical equipment manufacturing plants, and high-voltage testing laboratories.
FRCAC/DC voltage dividerTechnical Specifications:
type number |
FRC-50 |
FRC-100 |
FRC-150 |
FRC-200 |
FRC-300 |
FRC-400 |
FRC-500 |
FRC-600 |
FRC-800 |
Voltage level(kV) |
50 |
100 |
150 |
200 |
300 |
400 |
500 |
600 |
800 |
DC frequency(Hz) |
<2 |
||||||||
Communication frequency(Hz) |
30~300 |
||||||||
AType accuracy(%) |
AC:1.5%/DC:1% |
AC:3%orDC:1.5 |
|||||||
BType accuracy(%) |
AC:1.0%/DC:0.5% |
AC:2%orDC:1.0 |
|||||||
CType accuracy(%) |
AC:0.5%/DC:0.5% |
0.5% |
0.5% |
AC:1%orDC:0.5 |
|||||
Impedance(MΩ) |
600 |
1000 |
1500M |
2000M |
3000M |
4000M |
5000M |
6000M |
8000M |
Capacitance(pF) |
320 |
180 |
150 |
120 |
100-500 |
100-500 |
100-500 |
100-500 |
100-500 |
Voltage divider ratio |
1000:1or10000:1Special proportions can be customized |
||||||||
Height(mm) |
450 |
650 |
1050 |
1350 |
1850 |
2500 |
3000 |
3600 |
5100 |
Sizemm) |
150×150 |
160×160 |
200×200 |
260×260 |
800×800 |
1200×1200 |
1500×1500 |
2500×2500 |
|
Cable impedance(Ω) |
50 / 75 |
||||||||
measurement range |
Ordinary display instruments have two ranges, except for smart kilovolt meters |
Ordinary display instruments have two ranges, except for smart kilovolt meters |
|||||||
Cable length (meters) |
3 |
4 |
5 |
6 |
8 |
10 |
15 |
20 |
30 |
Weight(kg) |
5.5 |
6.9 |
10.6 |
14.1 |
23.5 |
48.2 |
75 |
125 |
150 |
Filling medium |
Imported dry polymer materials |
||||||||
Temperature range for use |
0℃~45℃ |
||||||||
relative humidity |
<85%RHNo condensation |
||||||||
altitude |
<1500Rice, can be customized in high-altitude areas |
||||||||
Usage restrictions |
Indoor use or outdoor use under clear weather conditions |
||||||||