E-mail
wxhtdlkj@163.com
-
Phone
15365233638
-
Address
No. 6-24 Zhenfa 5th Road, Xinwu District, Wuxi City
Wuxi Hangtai Electric Power Technology Co., Ltd
wxhtdlkj@163.com
15365233638
No. 6-24 Zhenfa 5th Road, Xinwu District, Wuxi City
HTPA/HTPDStandard voltage dividerThe voltage level is as high as 1200kV, with an accuracy of up to 0.02%. In accordance with JJG 496-2016 "National Metrology Verification Regulations", the series of products have been redesigned to include both AC and DCStandard voltage dividerLighter in size, better stability, and all core components are imported from abroad. After rigorous screening and over 30 tests, the excellent performance of the product is guaranteed. Applicable to pilot testing institutes at all levels nationwide, national, provincial, and municipal quality and technical supervision bureaus, or various high-voltage laboratoriesStandard voltage dividerDue to its high accuracy, it can measure relatively small changes in AC/DC voltage, providing a reliable measurement method for analyzing various materials, precision measuring voltage, or calibrating various voltages.
Product Alias
Precision communicationStandard voltage dividerAC voltage divider, DCStandard voltage dividerDC voltage dividerStandard voltage dividerPrecision DCStandard voltage dividerCommunicationStandard voltage divider
Product Features
1. Lightweight and stable.
2. High measurement accuracy.
3. Adopt imported core components.
HTPA/HTPDStandard voltage dividertechnical indicators
Model parameters | ||
Project Name |
HTPA communicationStandard voltage divider |
HTPD DCStandard voltage divider |
voltage level |
AC:0-1200kV |
DC:0-1200kV |
accuracy |
AC:0.1%、0.2% |
DC:0.2%、0.1%、0.05% |
Voltage divider ratio |
1000:1 |
1000:1, 100000:1 (special voltage ratios can be customized) |
interface |
It can be directly connected to high-precision multimeters such as Agilent and Fluke without considering the influence of input impedance |
|
Operating temperature |
0℃-45℃ |
|
Measuring temperature |
20℃-25℃ |
|
relative humidity |
<85%RH |
|
altitude |
Less than 2000 meters (customized for high altitudes) |
|
Specification |
HTPD- 30 |
HTPD- 50 |
HTPD- 100 |
HTPD- 200 |
HTPD- 300 |
HTPD- 400 |
HTPD- 500 |
HTPD- 800 |
HTPD- 1000 |
HTPD- 1200 |
Rated voltage (kV) |
30 |
50 |
100 |
200 |
300 |
400 |
500 |
800 |
1000 |
1200 |
Impedance (MW) |
30 |
50 |
100 |
200 |
300 |
400 |
500 |
800 |
1000 |
1200 |
Voltage divider ratio |
10000:1/100000:1 |
100000:1 |
||||||||
Accuracy (%) |
0.1%/0.05%/0.02% |
0.1%/0.05% |
||||||||
Annual stability |
≤0.02% |
|||||||||
Measure voltage type |
DC |
|||||||||
ambient temperature |
20℃±10℃ |
|||||||||
relative humidity |
<80% RH without condensation |
|||||||||
insulation method |
Shell insulating oil |
|||||||||
Height (meters) |
0.4 |
0.6 |
0.9 |
1.6 |
2.7 |
3.2 |
4.5 |
6 |
8 |
10 |
Length * Width (meters) |
0.3 |
0.5 |
0.5 |
0.8 |
1.2 |
1.5 |
1.8 |
2.5 |
3 |
3.5 |
Weight (kg) |
25 |
35 |
45 |
165 |
235 |
275 |
335 |
450 |
550 |
650 |
Output impedance (kW) |
0.6/6 |
1/10 |
2/20 |
4/40 |
6/60 |
8 |
10 |
16 |
20 |
24 |
Rated output voltage (V) |
0.3/3 |
0.5/5 |
1/10 |
2/20 |
3/30 |
4 |
5 |
8 |
10 |
12 |