E-mail
1114335075@qq.com
-
Phone
13115197889
-
Address
Wujin District, Changzhou City, Jiangsu Province
Changzhou Tonghui Intelligent Technology Co., Ltd
1114335075@qq.com
13115197889
Wujin District, Changzhou City, Jiangsu Province
SF6 gas concentration monitoring system
The system conducts real-time online monitoring of SF6 gas and oxygen, and alarms when SF6 concentration exceeds the standard or oxygen deficiency occurs. It automatically links the fan to work, which can effectively avoid personnel health and safety accidents caused by high SF6 concentration and decreased proportion of oxygen concentration in indoor local environments.
Mainly used in indoor scenarios such as GIS rooms and SF6 gas filling cabinets filled with SF6 gas.

architecture diagram

SF6 gas concentration monitoring systemFeatures:
SF6 gas, oxygen concentration, temperature, and humidity detection function in the environment
Real time display function of telemetry and remote signaling for all monitoring points in the environment
SF6 gas concentration exceeding the standard and oxygen deficiency alarm function, forced exhaust function and automatic exhaust function
Automatic start function of the fan when an alarm is triggered Timed automatic exhaust function
Manually force all fans to start or stop
Historical data query, display, and storage functions
Remote sensing value historical curve trend query and display function
Enter the GIS or distribution room to automatically report the current environmental status function
Multiple monitoring point configuration function in different regions
Can provide communication protocols and interface with substation backend databases
Multi point networking function, reserved for integration with backend monitoring and fire protection systems
Sound and light, voice alarm function, and remote alarm function
Supports standard Modbus RTU/TCP/104/61850 upload protocol

working environment
Working voltage: AC/DC 220V ± 10%, 50Hz
Power consumption:<10W at rated voltage
monitoring parameters
SF6 gas concentration measurement range: 0-3000ppm
SF6 concentration over limit alarm point: 1000ppm (national standard value), accuracy<5% FS
Oxygen content detection range: 0-25%
Hypoxia alarm point: 18% (national standard value), accuracy<1% FS
Temperature detection range: -30 to+99 ℃ (accuracy ± 0.5 ℃)
Humidity detection range: 10-99% RH: accuracy ± 0.5% RH
Other parameters
Remote communication method: 485/Ethernet
On site host dimensions (mm): L330 × W250 × H65
Detection unit size (mm): L162 × W150 × H38
Monitoring historical data storage capacity: 5 million records
Touch screen size: 7 inches
Installation method of host and detection unit: wall mounted