E-mail
yzbrave@qq.com
-
Phone
13390665885
-
Address
Room 312, No. 98, Mount Taishan East Road, Baoying County
Yangzhou Baiyue Electric Co., Ltd
yzbrave@qq.com
13390665885
Room 312, No. 98, Mount Taishan East Road, Baoying County
50KW sheath meltblown cloth fin heater

50KW sheath meltblown cloth fin heater
summary:
Meltblown cloth heater is an electric heating device mainly used to heat gas flow, commonly known as air heater or gas heater. It is equipped with multiple baffles (guide plates) in its inner cavity to guide the flow of gas and prolong the residence time of gas in the cavity, thereby fully heating the gas, uniformly heating it, and improving heat exchange efficiency.
50KW sheath meltblown cloth fin heater
Technical Features:
1. The heating and cooling rates are fast, up to 10 ℃/S, with stable control and a smooth heating curve.
2. Adopting * * electric heater and temperature control method, with high precision, small temperature deviation, and thermal efficiency of over 90.
3. It has functions such as over temperature alarm, anti dry burning, pressure protection, etc., and the heater has a long service life.
4. The design temperature can reach 600 ℃, and the outer wall temperature is controlled at 50-60 ℃
5. Good mechanical performance: Because its heating element is made of alloy material, it has better mechanical performance and strength than any heating element under the impact of high-pressure gas flow. This is more advantageous for systems and accessory tests that require long-term continuous gas heating.
6. Single power can be customized.
Shield type heaterAttention:
1. The heater control part is a * * instrument, and should be handled with care during transportation. It is strictly prohibited to impact or hit it.
2. The cylinder part should be lifted reasonably to avoid deformation and damage to the internal heating elements.
3. The heater and control cabinet are placed in the warehouse and are strictly prohibited from being exposed to rain.
Shield type heaterCommon faults and maintenance: Fault 1: The digital display does not work. Check if the air switch is closed and if the control circuit is intact. Fault 2: The heater temperature does not rise. Check if the fuse is intact and if the gas heater is damaged. Fault 3: Three phase imbalance. Check if the three-phase incoming voltage is missing phase. Open the protective cover of the air heater and use a multimeter to check if a single electric heating element is open circuited. For faults that cannot be resolved by oneself, skilled technicians should be hired to solve them (or consult our customer service personnel). (Meltblown fabric heater can be customized according to customer requirements, providing drawings, voltage, power, and size)