Tianjin Yinshun YC-J gantry crane rubber sheathed cable 5 * 16mm2 $r $n $r $nYC-J steel wire reinforced rubber sheathed cable (enterprise standard cable) is a cable for cranes, electric hoists, elevators and other equipment. YC-J cable is a heavy-duty steel wire reinforced rubber sheathed wire, while YCW-J is used in the field and has a certain degree of weather resistance
Product Details

Tianjin Yinshun YC-J gantry crane rubber sheathed cable 5 * 16mm2

YC-J steel wire reinforced rubber sheathed wire (enterprise standard cable) is a cable for equipment such as cranes, electric hoists, and elevators. YC-J cable is a heavy-duty steel wire reinforced rubber sheathed wire. YCW-J cable is used in the field and has a certain degree of weather resistance. YZ-J cable (also known as YZG cable) is a steel wire reinforced medium-sized rubber sheathed flexible cable. The steel wire reinforced type increases the tension of the rubber sheathed cable. This type of cable is produced according to enterprise standards

Purpose:
Special rubber sheathed cable products are used for household appliances, power tools, and various mobile electrical equipment with AC rated voltage of 450/750V and below.
Use
(1) The rated voltage Uo/U of YZ type is 300/500V, while YC type is 450/750V.
(2) The long-term allowable working temperature of rubber sheathed wire core shall not exceed 65 ℃.
(3) W-shaped cables have weather resistance and certain oil resistance, making them suitable for use outdoors or in situations where they come into contact with oil stains.
(4) ZR type cables have flame retardant properties. -J is a steel wire reinforced type

Four core three large and one small structure cable allows continuous flow

model

Specifications
Number of cores multiplied by the cross-sectional area of the scale (mm2)

Conductive wire core mm

The largest DC resistance at 20 ℃

Current carrying capacity A



Copper core Ω/km

Tin plated copper core Ω/km








450/750V



YC-J
245IEC66
(YCW-J)






3×2.5+1×1.5

49/0.25 30/0.25

7.98

8.21

26


3×4+1×2.5

56/0.30 49/0.25

4.95

5.09

34


3×6+1×4

84/0.30 56/0.30

3.30

3.39

43


3×10+1×6

84/0.40 84/0.30

1.91

1.95

63


3×16+1×6

126/0.40 84/0.30

1.21

1.24

84


Tianjin Yinshun YC-J gantry crane rubber sheathed cable 5 * 16mm2Transportation and storage of wires and cables
During transportation, it is strictly prohibited to throw cables or cable reels containing cables from a height, especially at lower temperatures (usually around 5 ℃ or below). Throwing or dropping cables may cause insulation and sheath cracking.
2. Avoid storing cables in an exposed manner in the open air as much as possible, and cable reels are not allowed to be laid flat.
When lifting packaging, it is strictly prohibited to lift several plates at the same time. On vehicles, ships, and other transportation vehicles, cable reels should be secured using appropriate methods to prevent collisions or tipping over, in order to prevent mechanical damage to the cables.
4. Cables must not come into contact with acids, alkalis, and mineral oils, and must be stored separately from these corrosive substances There shall be no harmful gases that damage insulation or corrode metals in the warehouse where cables are stored.
During the storage period, cables should be rolled regularly (once every three months in summer, and may be extended at discretion in other seasons). When rolling, roll the storage tray upside down to prevent the bottom from getting damp and rotting. When storing, it is important to regularly pay attention to whether the cable head is intact and undamaged.
The storage period of cables is limited to the product's delivery date, generally not exceeding one and a half years, and the longest should not exceed two years.



Due to market raw material prices, there may be changes in product prices. Please confirm by phone before placing an order to avoid inconvenience and losses caused by price changes. The pictures are for reference only, and the actual products are subject to our company's standards. Our company has the final interpretation right.

Mining rubber sheathed flexible cable with a construction period of 5000 metersMining rubber sheathed flexible cable with a construction period of 5000 meters



1、 Mining rubber sheathed cable: execution standardMT818.5-1999
MY
Mining rubber sheathed cable(GB12972—91MYRubber sheathed cables are practical for AC extra voltageUo/Ufor3.6/6KVCopper core rubber insulated rubber sheathed mining flexible cable with copper core and below.

2、 Rated voltage of mining rubber sheathed cableUo/Ufor0.38/0.66and0.66/1.14KV

The long-term operating temperature of the cable conductor is65

The minimum bending radius of a cable is the diameter of the cable6times

3、 Model Table of Mining Rubber sheathed Cables;

model

name

main purpose

MY-0.38/0.66

Mining mobile rubber sheathed flexible cable

The rated voltage is0.38/0.66KVPower connection of various underground mobile coal mining equipment

MYP-0.38/0.66

Mining mobile shielded rubber sheathed flexible cable

The rated voltage is0.38/0.66KVPower connection of various underground mobile coal mining equipment

MYPT-0.66/1.14

Mining mobile shielded rubber soft sheathed cable

The rated voltage is0.66/1.14KVPower connection of various underground mobile coal mining equipment

MYPTJ-3.6/6KV

Mining monitoring type shielded rubber sheathed flexible cable

The rated voltage is3.6/6KVPower connection of various underground mobile coal mining equipment


JHSB 3 * 50 Cable JHS Waterproof Cable 500v Price
Waterproof rubber sheathed cables are used for transmitting electrical energy on submersible motors with AC voltage of 500V and below.
JHSB 3 * 50 Cable JHS Waterproof Cable 500v Price
The standard cable JHS 4 * 25 submersible pump cable has a long-term allowable working temperature of 65 ℃.
Specification: number of cores x cross-section/mm2
Single core, three core, four core
1×4 3×2.5 3×2.5+1×1.5
1×6 3×4 3×4+1×2.5
1×10 3×6 3×6+1×4
1×16 3×10 3×10+1×6
1×25 3×16 3×16+1×6
1×35 3×25 3×25+1×6
1×50 3×35 3×35+1×6

High voltage cable UGFP high voltage rubber sheathed flexible cable

6kV mining rubber sheathed flexible cable - high-voltage mining cable
1. Model and name: UGF-6000V mining rubber sheathed flexible cable
UG-6000V mining rubber sheathed flexible cable
2. Execution standard: 3. Purpose: Mobile power distribution equipment and mining machinery with AC rated voltage of 6kV and below; Lifting and transportation machinery, etc. 4. Usage: The rated voltage of the cable is 6kV;
The long-term operating temperature of the cable is+65 ℃.
The minimum bending radius of the cable is 6 times the diameter of the cable. 5. The specifications of the cable should comply with the provisions of Table 1
Number of cores x number of cross-sectional conductor structures/wire diameter Insulation nominal thickness Sheath nominal thickness Outer diameter Main core DC resistance Euro/km

High voltage cable UGFP high voltage rubber sheathed flexible cable
Main line core, ground wire core
ugf 3×6+1×6 84/0.30 4.5 1.4 6.0 40.3 3.30
ugf 3×10+1×10 84/0.40 4.5 1.6 6.0 43.8 1.91
ugf 3×16+1×16 126/0.40 4.5 1.6 6.0 46.8 1.21
ugf 3×25+1×16 196/0.40 4.5 1.6 6.0 49.3 0.78
ugf 3×25+1×16 276/0.40 4.5 1.6 6.0 52.0 0.554

6. Technical performance: The direct current resistance of the conductor at 20 ℃ is shown in Table 1.
The insulation resistance between finished cable cores, converted to a length of 1km and a temperature of 20 ℃, should not be less than 100 megaohms.
The main cores of the finished cable and between the main cores and the grounding wire should be able to withstand an AC voltage test of 50 Hz 15000 volts for 5 minutes without breakdown.

National standard cableway supported communication cable HYAC price

Product Introduction - Local Communication Cable HYA Oil Filled Communication Cable HYAT Self Supporting Communication Cable HYAC Armored Communication Cable HYA53, HYAT53, HYA23, HYAT23 Local Communication Cable HPVV All Plastic Local Communication Cable HYA Communication Cable HYAT Communication Cable HYAC Communication Cable HYA53 Communication Cable HYA23 Communication Cable HYAT23 Communication Cable HYA Communication Cable HYAT Communication Cable HYA Local Communication Cable HYAT Local Communication Cable HYACHYAHYA53 Armored Communication Cable
Communication cable model HYA HYACHYAPHPVV HYV HJVV HYY ZRC-HYA
Armored communication cable HYA22 HYV22 HYAT22 HYY23 HYYT23 HYA23 HYAT23 HYA53 HYAT53
Armored communication cable HYA33 HYAT33 HYA53 HYY23 HYYT33 HYY33
Oil filled communication cable HYAT HYYT HYAT23 HYAT53
National standard cableway supported communication cable HYAC priceUrban communication cable
Implementation standard for urban communication cables: YD/T322-1996-
HYA urban communication cable (widely used in the construction of metropolitan area network communication networks, mainly installed overhead and pipeline, mainly transmitting audio signals)
HYAT filled communication cable (used in the construction of metropolitan area network communication networks, mainly installed in pipelines, with water blocking effect, no need for inflation protection, mainly transmitting audio signals)
HYAC self-supporting communication cable(Used in the construction of metropolitan area network communication networks, it is installed overhead, easy to construct, and mainly transmits audio signals)
HYAT53 filled armored cable (used in complex environments of metropolitan area network communication network construction, directly buried underground, with water blocking and rodent bite prevention effects, no need for inflation protection, mainly transmitting audio signals)
Sales and production of various types of flame-retardant communication cables, mining communication cables, mining signal cables, mining flame-retardant signal cables, mining flame-retardant control cables, mining flame-retardant communication cables, mining cables, mining communication cables, mining signal cables, mining communication cables, mining communication cables, mining control cables, mining monitoring cables, sensor cables, signal cables, intrinsically safe explosion-proof cables, control cables, computer cables, flame-retardant cables, fire-resistant cables, urban communication cables, railway signal cables, communication flame-retardant power lines, etc. The main products of mining cables include: MHYV, MHYA32, MHYAV, MHY32, MHYVR, MHYVP, MHYVRP, MKVV, MKVV22, MKVV32, etc. The certificate of Coal Safety Mark is complete in specifications, and the product is widely used in various coal mine systems and coal mine monitoring systems. The product has been used in dozens of coal industry groups and mines across the country, and has received high praise and acclaim.

Product Description: Our factory produces communication cables suitable for fixed installation, overhead or underground in the city
HYA: Copper core solid polyolefin insulated moisture-proof layer polyethylene sheathed urban communication cable
HYAT: Copper core solid polyolefin insulated filled moisture-proof layer polyethylene sheathed urban communication cable
HYAC: Copper core solid polyolefin insulated self-supporting moisture barrier layer polyethylene sheathed urban communication cable
HYA53: Copper core solid polyolefin insulation, moisture barrier layer, polyethylene sheath, steel plastic tape armor, polyethylene sheath, urban communication cable
HYAT53: Copper core solid polyolefin insulation filled moisture-proof layer polyethylene sheath steel plastic tape armored polyethylene sheath urban communication cable
HYA22: Copper core solid polyolefin insulation, moisture barrier layer, polyethylene sheath, steel tape armor, polyvinyl chloride sheath, urban communication cable
HYA23: Copper core solid polyolefin insulation, moisture barrier layer, polyethylene sheath, steel tape armor, polyethylene sheath, urban communication cable
HYAT22: Copper core solid polyolefin insulated filled moisture-proof layer polyethylene sheathed steel tape armored polyvinyl chloride sheathed urban communication cable
HYAT23: Copper core solid polyolefin insulated filled moisture-proof layer polyethylene sheathed steel tape armored polyethylene sheathed urban communication cable
Purpose: Self supporting non filled cables are suitable for urban and rural telecommunications lines in local telecommunications networks, as well as network cables for accessing public networks. The hanging wire and cable use the same outer protective layer, which is economical, practical, and easy to install and lay. Under environmental conditions ranging from 30 ° C to 60 ° C, the mechanical and electrical properties of the cable remain unchanged.
Structure: Wire: Annealed bare copper wire with diameters of 0.32, 0.4, 0.50, 0.60, 0.70, 0.80, 0.90mm.
Insulation material: high-density polyethylene or ethylene/propylene copolymer, the color of the insulation wire meets the full chromatographic standard.
Insulated wire pair: Two insulated wires of different colors are twisted into pairs at different pitches, and a specified chromatographic combination is used for identification. Cable core structure: Based on 25 pairs as the basic unit, cables exceeding 25 pairs are combined by unit, and each unit is wrapped with a unit cable tie of the specified color spectrum to identify different units. 100 pairs or more of cables are equipped with 1% spare pairs.
Cable core wrapping tape: Wrap it with polyester film tape.
Shielding: Use rolled or non rolled metal tape to wrap the cable core longitudinally, with overlapping on both sides.
The plastic film coated on the surface of the shielding tape is bonded to the protective layer, and the sheath is made of black low-density polyethylene.

Sales process:
1. Advance payment of 30%, arrange production, complete production of goods, arrange full payment for shipment, product packaging, instruction manual, invoice, and delivery note. All goods are delivered free of charge to customers
After-sales service
1. Within one week of product delivery, our after-sales service department staff will follow up and consult with customers based on their feedback until they are satisfied. Please contact our company quickly within the warranty period to facilitate timely repair and replacement for users. The warranty period is one year.
2. All complaints related to product quality: respond within 1 hour, arrive at the scene within 24 hours, and determine the handling measures based on the complaint situation for repair and replacement. Any costs related to product quality during the shelf life will be borne by our company.

Communication Cable - Armored Flame Retardant Cable HYV22-24 * 2 * 0.5mm2 Price

(1) Mining communication cable MHYV complies with: MT386-1995 "Test Methods and Judgment Rules for Flame Retardant Cables Used in Coal Mines" and Q/TX 002-2006 "Flame Retardant Communication Cables Used in Coal Mines" Mining communication cable MHYVR cable (PUYVR cable, mining riot control cable) (1 × 2 1 × 4 3 × 2 4 × 2 5 × 2 10 × 2 logarithmic) × 7/0.28 7/0.37/0.43 7/0.52 (conductor diameter)
MHYVR1×2×7/0.43+1×2×7/0.3
(2) Mining communication cable MHYVRP cable (1 × 2 1 × 4 3 × 2 4 × 2 5 × 2 10 × 2 pairs) × 7/0.28 7/0.37 7/0.43 7/0.52 (conductor diameter) Purpose: for flat and inclined tunnels with high mechanical damage
1. Soft core copper conductor 2. Insulation 3. Braided shielding 4. Sheath

MHYV cable (four steel and three copper) (1 × 2 1 × 4 3 × 2 4 × 2 5 × 2 10 × 2 pairs) x 7/0.28 (conductor diameter)
1. Soft core copper conductor (four steel and three copper) 2. Insulation 3. Sheath Yan Peishuo
(3) Execution standard: Enterprise standard Q/TX002-2006 This standard is applicable to copper core polyethylene sheathed fixed and mobile communication flame-retardant cables used in coal mines.
Cable model, name, specification and purpose
Model Name Specification Purpose
MHYV (PUYV) polyethylene insulated flame-retardant polyvinyl chloride sheathed mining signal cable 2-5
On 7/0.28, it is used for flat lanes, inclined lanes, and mechanical and electrical tunnels

Communication Cable - Armored Flame Retardant Cable HYV22-24 * 2 * 0.5mm2 Price
MHJKV (PUJKV) polyethylene insulated flame-retardant polyvinyl chloride sheathed reinforced mining communication cable 2-5
7/0.28 (three steel and four copper) is used for flat and inclined tunnels, with good tensile strength
MHYVP coal mine polyethylene insulated braided shielded polyvinyl chloride sheathed communication cable (5-10) * 2 * (0.75-1.5) is used for signal transmission in places with high electric field interference and is suitable for fixed installation
MHY32 coal mine polyethylene insulated steel wire with PVC sheath communication cable (5-19) * 2 * (0.75-1.5) used for main signal transmission in level tunnels, vertical shafts or inclined shafts
MHYVR coal mine polyethylene insulated polyvinyl chloride sheathed communication flexible cable (5-10) * 2 * (0.75-1.5) is used for ordinary signal transmission in mines and can be moved for use
MHYBV (PUYBV) coal mine polyethylene insulated galvanized steel wire braided armor flame-retardant polyvinyl chloride sheathed communication cable 5-50
1/0.8 is used for flat and inclined tunnels with high mechanical impact
MHYAV (PUYAV) coal mine polyethylene insulated aluminum/polyethylene bonded protective layer flame-retardant polyvinyl chloride sheathed communication cable 10-100
1/0.81/1.0 is used as a communication line for damp inclined shafts and alleyways
MHYA32 (PUYA32) coal mine polyethylene insulated aluminum/polyethylene bonded protective layer galvanized steel wire armored flame-retardant polyvinyl chloride sheathed communication cable 10-100
1/0.81/1.0 used for communication lines in coal mine shafts and inclined shafts
Flame retardant communication cables for coal mines... MH polyethylene insulation... Y copper wire core... Aluminum polyethylene bonding protective layer omitted... A polyethylene inner protective layer omitted... Copper wire braided armor omitted... B blue flame retardant polyvinyl chloride sheath... V steel wire armor blue flame retardant polyvinyl chloride sheath... 32 copper wire braided shielding... P soft wire core... R

The sustained and rapid growth of the Chinese economy has provided a huge market space for cable products. The strong force of the Chinese market has attracted the world's attention to the Chinese market. In the short decades of reform and opening up, the huge production capacity formed by China's cable manufacturing industry has impressed the world. With the continuous expansion of China's power industry, data communication industry, urban rail transit industry, automobile industry, shipbuilding and other industries, the demand for wires and cables will also grow rapidly, and there is still huge development potential for the wire and cable industry in the future.
In November 2008, in response to the global financial crisis, the Chinese government decided to invest 4 trillion yuan to boost domestic demand, of which more than 40% was used for the construction and renovation of urban and rural power grids. The national wire and cable industry has once again had a good market opportunity, and wire and cable enterprises in various regions have seized the opportunity to welcome a new round of urban and rural power grid construction and renovation.
The wire and cable industry is the second largest industry in China, second only to the automotive industry, with a product variety satisfaction rate and domestic average. Worldwide, China's total output value of wires and cables has surpassed that of the United States, becoming the world's largest producer of wires and cables. With the rapid development of China's wire and cable industry, the number of new enterprises continues to rise, and the overall technological level of the industry has been greatly improved



Similar Product Recommend