Welcome Customer !

Membership

Help

Shanghai Zhenghe Pump Valve Manufacturing Co., Ltd
Custom manufacturer

Main Products:

ybzhan>Products

Shanghai Zhenghe Pump Valve Manufacturing Co., Ltd

  • E-mail

    2781756371@qq.com

  • Phone

    86-13585552756

  • Address

Contact Now

ZG5-1 corrugated storage tank flame arrester

NegotiableUpdate on 01/06
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
ZGB-1 Overview of Corrugated Tank Fire Arrester Products for Petroleum Tanks Corrugated Fire Arresters, Used for Installing Important Safety Equipment on Fixed Top Tanks
Product Details

Overview of ZG5-1 Corrugated Storage Tank Flame Arrester Product

The corrugated flame arrester for oil storage tanks is used to install important safety equipment on fixed top tanks. Its function is to allow flammable and explosive gases to pass through, and to prevent suffocation of flames. The flame arrester has a reasonable structure, light weight, corrosion resistance, and qualified explosion resistance performance. It has been tested for 13 consecutive subsonic flame tests and has been able to block fire every time. Easy to maintain, easy to install, no need to disassemble the breathing valve during inspection. The fire resistance performance is qualified, and there is no tempering phenomenon after 1 hour of fire resistance test. The flame arrester core is made of stainless steel material, which is corrosion-resistant and easy to clean. The shell water pressure test is qualified.

Working principle of ZG5-1 corrugated storage tank flame arrester

The main function of the corrugated flame arrester for storage tanks is to allow flammable and explosive gases to pass through, and to prevent suffocation of flames that enter the storage tank from the outside. Usually installed on storage tanks and pipelines that transport or discharge flammable and explosive gases, it is a safety device used to prevent flames of flammable gases and liquids and to prevent dangerous accidents caused by backfire. Its function is to allow flammable and explosive gases to pass through, and to prevent suffocation of flames.

The corrugated flame arrester for storage tanks adopts a stainless steel "N" shape, with double-layer corrugated bands as the flame arrester core, and a cross shaped bracket (or Y-shaped bracket pressed on the surface) inside the core to enhance its reliability and prevent the explosive pressure generated by the ignited medium from dissipating. Based on this principle, the height of the triangular hole is designed to prevent the flame from passing through, and sufficient channel length is added to absorb the heat of the flame, making it extinguish in the core and avoiding the possibility of gas reigniting at the other end of the core.

Scope of application of ZG5-1 corrugated storage tank flame arrester

This flame arrester is suitable for storage tanks, Class A with a flash point below 28 ℃, oil products, hydrogen oxygen liquefaction, and kerosene, diesel, toluene, crude oil, etc. with a flash point below 60 ℃. It can be used in conjunction with a breathing valve or as a standalone device on the ventilation pipes of internal floating roof oil tanks and underground oil tanks at gas stations.

Structure diagram of ZG5-1 corrugated storage tank flame arrester

波纹储罐阻火器

ZGB-1 corrugated storage tank flame arrester component material:

Valve body material

Carbon steel WCB, stainless steel 304, 316

Fire retardant core material

Stainless steel explosion-proof and fire-resistant corrugated plate

Sealing material

Oil resistant asbestos rubber, PTFE tetrafluoroethylene

Environmental temperature ℃

≤480

Nominal pressure (MPa)

0.6~5.0

Explosion proof level

BS5501:ⅡA、ⅡB、ⅡC

ZGB-1 corrugated storage tank flame arrester national standard flange connection external dimensions: GB, JB


Specifications

Installation size (mm)

D2

D

L

H

N-d

DN50

Φ110

Φ140

220

235

4×14

DN80

Φ150

Φ185

280

270

4×18

DN100

Φ170

Φ205

325

275

4×18

DN150

Φ225

Φ260

425

290

8×18

DN200

Φ280

Φ315

495

305

8×18

DN250

Φ335

Φ370

595

320

12×18

DN300

Φ395

Φ435

655

405

12×23

ZGB-1 corrugated storage tank flame arrester American standard flange connection external dimensions: ANSI, API, ASME available for JIS standards


Specifications

Installation size (mm)

D2

D

L

H

N-d

2'

Φ120.5

Φ152

220

235

4×19

3'

Φ152.5

Φ190

280

270

4×19

4'

Φ190.5

Φ229

325

275

8×19

6'

Φ241.5

Φ279

425

290

8×22

8'

Φ298.5

Φ343

495

305

8×22

10'

Φ362

Φ406

595

320

12×25

12'

Φ432

Φ483

655

405

12×25

Ordering Notice:

Please specify detailed parameters such as product name, nominal diameter, pressure rating, material, flange standard, and operating pressure when placing an order. The above product dimensions are standard universal models. If you need other specifications, non-standard product design drawings and detailed parameters, or if the environment is very important for use and complex, please contact our company for our experts to review and serve you wholeheartedly.

Our company has always adhered to the principles of integrity, quality, and customer first, providing high-quality products and after-sales service to our customers. Welcome to inquire by phone.