E-mail
ryu@ultrablue-sci.com
-
Phone
13331917708
-
Address
Room 302, Building 11, 999 Jiangyue Road, Minhang District, Shanghai
Shanghai Beilan Optoelectronics Technology Co., Ltd
ryu@ultrablue-sci.com
13331917708
Room 302, Building 11, 999 Jiangyue Road, Minhang District, Shanghai
SMARTSens-D UV-C radiometer
Real time UV-C dose monitoring
The SMARTSens-D UV-C measuring instrument is a calibrated irradiance meter that enables real-time monitoring of UV-C dose to verify the effectiveness of UV-C surface disinfection. By using SMARTSens-D software, it is easy to monitor the process of UV-C disinfection system and monitor the dose performance of UV-C disinfection system in real time, or integrate digital instruments as components into UVGI system software using the provided SDK.
Features:
Real time dose monitoring to ensure disinfection reliability and exposure safety
Instant system performance feedback can immediately troubleshoot and improve product performance reliability
·Track regional security levels to optimize efficiency
The SMARTSens-D radiometer has * * application flexibility and high UV-C measurement accuracy. Each sensor can be calibrated based on the irradiance response of one or more UVGI wavelengths and light sources (254 nm low-pressure mercury lamp, 265 nm LED lamp, and 275 nm LED lamp) that you have selected, thereby improving application flexibility and measurement accuracy.
Irradiance response calibration is sold separately (please refer to the 'MARTSens UV-C Calibration' product for details)
SMARTSens-D Integrated Sensor
SMARTSens-D integrated digital UV-C sensor can be used as a single sensor to monitor UV-C irradiance and dose. Multiple sensors can be networked and monitored from a central location.
SMARTSens-D external sensor
Each controller in the SMARTSens-D digital radiometer can be equipped with one to four sensors. An appropriate number of UV-C dose monitoring sensors can be selected in the UVGI system.
Internet connected sensors
SMARTSens-D uses a simple USB connection, allowing you to deploy multiple sensors on the same operating system instance and use the same software platform to monitor UVGI systems, enclosures, or rooms.
SMARTSens-D UV-C radiometer Specifications:
1. Integrated Sensor:
UVC-HISI-001 Controller Irradiance Meter: Integrated Sensor and Controller
Number of sensors: One (Integrated)
Calibration of irradiation responsivity at 254 nm, 265 nm, and/or 275 nm is optional
Range of irradiance:~20 μ W/cm2 * * * 20 mW/cm2
User interface control software and SDK
Dimensions 41 mm (L) x 41 mm (W) x 29 mm (H)
Part number AA-01603-200
2. External Sensors:
UVC-HISC-001 Controller Single Channel Controller (SSC-1000)
Number of sensors: one (external)
Calibration of irradiation responsivity at 254 nm, 265 nm, and/or 275 nm is optional
Range of irradiance:~20 μ W/cm2 * * * 20 mW/cm2
User interface control software and SDK
Controller size 41 mm (L) x 41 mm (W) x 17 mm (H)
Detector size 28 mm (L) x 28 mm (W) x 13 mm (H)
Part number AA-01603-101
UVC-HISC-002 Controller Four Channel Controller (SSC-4000)
Two sensors (external)
Calibration of irradiation responsivity at 254 nm, 265 nm, and/or 275 nm is optional
Range of irradiance:~20 μ W/cm2 * * * 20 mW/cm2
User interface control software and SDK
Controller size 42 mm (L) x 42 mm (W) x 29.4 mm (H)
Detector size 28 mm (L) x 28 mm (W) x 13 mm (H)
Part number AA-01603-102
UVC-HISC-003 Controller Four Channel Controller (SSC-4000)
Three sensors (external)
Calibration of irradiation responsivity at 254 nm, 265 nm, and/or 275 nm is optional
Range of irradiance:~20 μ W/cm2 * * * 20 mW/cm2
User interface control software and SDK
Controller size 42 mm (L) x 42 mm (W) x 29.4 mm (H)
Detector size 28 mm (L) x 28 mm (W) x 13 mm (H)
Part number AA-01603-103
UVC-HISC-004 Controller Four Channel Controller (SSC-4000)
Four sensors (external)
Calibration of irradiation responsivity at 254 nm, 265 nm, and/or 275 nm is optional
Range of irradiance:~20 μ W/cm2 * * * 20 mW/cm2
User interface control software and SDK
Controller size 42 mm (L) x 42 mm (W) x 29.4 mm (H)
Detector size 28 mm (L) x 28 mm (W) x 13 mm (H)
Part number AA-01603-104
3. Calibrations
Calibration and programming calibration options for low pressure mercury 254 nm UVC-IRR-254HG irradiance response UVC-HISI-001, UVC-HISC-001
UVC-HISC-00 2、UVC-HISC-003、
UVC-HISC-004
Calibration frequency: one to four times for each irradiance meter
Calibrate the irradiance response of low-pressure Hg 254 nm
Part number AA-01603-300
Calibration and programming calibration options for irradiation response of 265 nm LED UVC-IRR-265 LED UVC-HISI-001, UVC-HISC-001
UVC-HISC-002、UVC-HISC-003、
UVC-HISC-004
Calibration frequency: one to four times for each irradiance meter
Calibrate the irradiance response of 265 nm LED
Part number AA-01603-301
Calibration and programming calibration options for 275 nm LED UVC-IRR-275 LED irradiation response UVC-HISI-001, UVC-HISC-001
UVC-HISC-002、UVC-HISC-003、
UVC-HISC-004
Calibration frequency: one to four times for each irradiance meter
Calibrate the irradiance response of 275 nm LED
Part number AA-01603-302